spacer
GMX International Logo.

GMX INTERNATIONAL
13771 Roswell Avenue, Suite A * Chino, California 91710
909-627-5700 * Fax: 909-627-4411
Email:

American FlagMade in the USAAmerican Flag

GMX International Logo.

Model 8000

Model 8000 GMX Magnetic Fluid Conditioner
For 2" to 14" Tubing or Pipe

GMX 8000


APPLICATIONS

Primary Applications

Residential, Commercial, Industrial, and Agricultural applications wherever hard water is present.

INSTALLATION

Please Note: Each Model 8000 set consists of two separate pieces. One piece has two north pole magnets. This is the side covered by the GMX label. The other piece has two south pole magnets. A system consists of one or two sets, held to the pipe by a common band. There should always be a 1"space between units.

Installation on 2" to 4" Pipe:

Install four sets 1" apart . The sets must be placed so that the north pole pieces are lined up with each other on the same side of the pipe, and the south pole pieces are in line with each other on the exact opposite side of the pipe.

Installation on 5" to 6" Pipe:

Install seven units 1" apart. The sets must be placed so that the north pole pieces are lined up with each other on the same side of the pipe, and the south pole pieces are in line with each other on the exact opposite side of the pipe.

Installation on 6" to 14" Pipe:

Install seven to 15 units depending on the diameter of the pipe. The north pole pieces of both sets in each unit must be placed side-by-side on one side of the pipe. The south pole pieces of both sets in each unit must be placed side-by-side on the opposite side of the pipe. (For example, if the two north pole pieces in the unit were placed at the 11:00 and 1:00 positions, then the two south pole pieces would be placed at the 5:00 and 7:00 positions.)

PROCEDURE FOR INSTALLATION

1. Position the Model 8000 units according to the preceding instructions.

2. Hold the units into position with fiberglass tape before installing the steel banding.

3. Hold the "rack" that comes with the steel banding so that the words " This Side Up" are facing you. Insert the end of the rack into the screw housing and turn the screw just enough to engage the rack.

4. Bend the end of the steel band toward the underside to form a hook. Insert this into the band slot in the housing.

5. Wrap the band snugly around the units.

6. Make a second bend [hook] 1" past the band slot in the rack. Secure the band ends behind the units.

7. Insert the hook into the band slot in the rack and flatten it to form the clamp. Any excess band must be folded back under the unit, or can be trimmed off. Tighten the screw with a screwdriver to the desired tension.

8. Carefully check the units to make sure they are firmly secured to the pipe before removing the tape.

SPECIAL NOTE

Use Caution:

The Model 8000 sets are heavy and can cause injury or damage if dropped. Before clamping them into place with the steel bands, secure the sets in place with fiberglass strapping tape.

Placement:

The direction the fluid flows through the pipe on which the units are installed makes no difference.

For best results when placing the Model 8000 to treat a particular area or appliance, place the units at least 8" to 12" upstream (before) the area or appliance to be treated.

Do not place the Model 8000 close to an electrical power line, or electrical equipment capable of generating strong electrical fields, such as a welder or large electrical motor. This can reduce the unit's effectiveness.

For maximum effectiveness magnetic fluid conditioning requires a smooth, calm, flow of fluid through the magnetic field. A partial of the treatment may even be triggered by turbulence. Therefore, always place the Model 8000 a minimum of 24"downstream (after) any pump or other turbulence-causing device.

Non-Ferrous Pipes Only:

Install the Model 8000 only on non-ferrous (PVC, plastic, copper,or stainless steel) pipe or tubing--not on steel or iron pipe. Don't place it on any pipe to which the magnets stick. The penetration of the magnetic field through iron or steel (except for stainless steel) pipe is minimal. In effect, the magnetic field travels along the exterior of such pipes preventing it from reaching the fluid. In such cases, replace and 18" to 24" section of steel pipe with either copper or PVC pipe, and then install the Model 8000 on that section.

Stabilization Period:

For a few weeks after installing the Model 8000 you may notice and increase in water turbidity (cloudiness). This is because scale is being removed from the system. During this stabilization period, carefully monitor filters, tanks, and sumps each week, and drain or clean them as needed.

Products |  GMX 400 |  GMX 800 |  GMX 848 |  GMX 8000 |  Ringmaster

GMX Selection and Placement PDF

Sharon Costanzo, CEO, at GMX Corporate Headquarters
Sharon Costanzo, CEO

GMX Corporate Headquarters
GMX International

GMX Corporate Headquarters

GMX Corporate Headquarters

GMX Corporate Headquarters

GMX Corporate Headquarters

GMX Corporate Headquarters

GMX Corporate Headquarters

Click on any image above to view gallery

spacer spacer spacer

 


Home  |  Company  |  Facts  |  Products  |  Installations  |  Testimonials

International Agents  |  Plumbing Contractors & Services |  Swimming Pool Contractors & Services  |  Downloads  |  Site Map - Search

 


Copyright ©2000-2019, All Rights Reserved, GMX Corporation

site maintainted by crestonecreations.com